Axial & Mixed Flow Pumps

Large-flow, low-head pumps for drainage, irrigation and flood control, in fixed and mobile arrangements.

Types
Mixed flow and vertical axial flow
Mixed flow
Electric, diesel or trailer set
Axial flow
Vertical, body length set by the project
Series
HW, ZLB
Blue mixed flow pump with a large inlet and an electric motor on a black base
On this page

Series

  • HW
  • ZLB

Axial flow and mixed flow pumps move very large volumes of water at low head. In an axial flow pump the impeller pushes the water along the shaft, like a propeller. In a mixed flow pump it pushes the water partly outward as well, which gives somewhat more head.

They are used for drainage, irrigation and flood control, where large volumes have to be lifted a short height. Mixed flow pumps are supplied as fixed or mobile sets; vertical axial flow pumps are built with the body length and support set by the project drawing.

Typical duties

  • Drainage
  • Irrigation
  • Flood control
  • Channel transfer

Supply forms

Mixed flow pumps come as electric, diesel or trailer sets. Vertical axial flow pumps are made to the installation.

  • Mixed flow, electric set

    A mixed flow pump and an electric motor on a base.

    Type and drive: Mixed flow; electric motor

    Choose it when mains power is available at the site.

  • Mixed flow, diesel set

    A mixed flow pump driven by a diesel engine on a base.

    Type and drive: Mixed flow; diesel engine

    Choose it when there is no mains power at the site.

  • Mixed flow, trailer set

    A diesel-driven mixed flow set on a wheeled trailer with support legs.

    Type and drive: Mixed flow; diesel engine, on a trailer

    Choose it when the pump has to move from one channel or pond to the next.

  • Vertical axial flow pump

    A long vertical pump body with the motor above the channel, made to the installation drawing.

    Type and drive: Axial flow; motor above the channel

    Choose it when a fixed pumping station lifts a very large flow over a short height.

Why axial and mixed flow pumps

A centrifugal pump gains head by throwing water outward. Where the head is low and the flow very large, it is more efficient to push the water along the axis instead. The impeller of an axial flow pump works like a ship propeller inside a pipe.

A mixed flow impeller sits between the two: it pushes water along the axis and outward, which gives it more head than an axial pump while still passing a large flow.

Mobile mixed flow pump set discharging a large stream of water at a riverbank

Construction

The drawing shows a vertical axial flow pump installed in a concrete channel, with the motor above.

  1. ImpellerA propeller-like or mixed flow impeller sized for a large flow.
  2. Casing or pump bodyA volute casing for mixed flow pumps; a long vertical body for axial flow pumps.
  3. Shaft and bearingsCarry the impeller and the thrust of the flow.
  4. Support and driveA base for mixed flow sets; a support and motor above the channel for axial flow pumps.

Compare with other water pumps

All of these pump clean water. They differ in the flow they pass, the head they build and where they are installed. The duty point of the system decides between them.

PumpFlowHeadBest known for
End Suction Centrifugal PumpsModerateModerateGeneral supply, circulation and transfer
Inline Pipeline PumpsModerateModerateSitting in the pipeline where space is tight
Split Case Double Suction PumpsLargeModerateLong running hours and easy maintenance
Horizontal Multistage PumpsLow to moderateHighHigh-head duty such as mine water lift and boiler feed
Vertical Multistage PumpsLow to moderateHighPressure boosting on a small floor area
Axial & Mixed Flow PumpsThis pageVery largeLowDrainage, irrigation and flood control
Self-Priming PumpsModerateModerateLifting from below pump level without a foot valve
Borehole Submersible PumpsLow to moderateModerate to highDrawing water from wells and boreholes

A comparison in general terms. Send your duty and we will say which type fits it.

Choosing an axial or mixed flow pump

Flow and head
The duty point; these pumps suit large flow and low head
Type
Mixed flow set, or vertical axial flow pump
Water levels
Highest and lowest levels at the intake and the outlet
Installation
Fixed, or on a trailer; for axial flow, the body length and support from the drawing
Drive
Electric motor, or diesel engine where there is no supply
Water
Clean or lightly loaded water; solids and debris

Typical axial and mixed flow pump duties

  • Drainage and flood control

    Lifting large volumes of water out of low-lying areas.

  • Irrigation

    Moving water from rivers and channels to fields.

  • Channel transfer

    Moving water between channels and basins.

From the works

  • Sets in the workshop
  • Sets loaded on a truck

Frequently asked questions

Axial flow or mixed flow pump?

Axial flow pumps suit the largest flows at the lowest head. A mixed flow pump gives more head for a large flow. The duty point decides between them.

Can the pump run on a diesel engine?

Yes. Mixed flow pumps are supplied as electric sets, diesel sets and diesel sets on a trailer.

What do you need to quote an axial or mixed flow pump?

Flow, head, the highest and lowest water levels, the installation arrangement and the drive. For an axial flow pump, a drawing of the installation helps most.

Request a quote for axial & mixed flow pumps

Send the flow, the water levels and the installation arrangement. A drawing of the site helps.

Flow rate
Total head
Pumped medium
Solids concentration
Particle size
Materials & wear resistance
Operating conditions

Prefer email or WhatsApp?sales@kunyuemech.comWhatsApp +86 182 4452 6981

Send your inquiry

Tell us about the duty. Technical details are optional.

Add technical details (optional)

We use your details only to answer your inquiry. See our Privacy Policy.